OCTOPUS HEAT

OCTOPUS HEAT ™

Save at least 30% on your energy bill with OCTOPUS HEAT™

Automatic control of heat consumption

With the OCTOPUS system, you can automatically set the temperature in the rooms – both those in use and those that are not.

The integration with Danfoss Ally™ and SONOFF products gives you many possibilities. For example, you can set the system to automatically turn on the heating 3 hours before arrival – and likewise, automatically lower the heat 2 hours before checkout, when guests are typically showering, packing, having breakfast, or already on their way out.

You can, of course, control all your rooms, including hotel rooms, meeting rooms, staff areas, etc., and different settings can be configured for each location/area.

Another way to save even more on your energy bill could be to configure a slight nighttime temperature reduction. Lowering the temperature by just a degree or two can make a big difference in the long run!

Other benefits include the ability to set a minimum and maximum temperature for guests – or a 'child lock' feature that completely prevents guests from manually adjusting the room temperature.

The system also checks for open windows (if the thermostat is near the window) and shuts off the heating during ventilation.

The thermostats are easy to install, as the entire system is wireless—and they fit most radiators.

Additionally, the system only requires an internet connection via a gateway before you can enjoy outstanding precision and impressive energy savings!

Example of a weekend stay:

  • 1 hour before check-in, the room temperature is automatically raised to 20 degrees.
    Guests can always adjust the temperature afterward within a range that you specify.
    We recommend between 16–24 degrees.

  • Kl. 23 er der nattesænkning til 17 grader, da vi regner med, at gæsten er gået i seng eller snart vil gøre det.

  • Kl. 5 hæves temperaturen igen til 20 grader, så værelset kan nå at blive varmere inden gæsten står op.

  • Kl. 10 sænkes temperaturen nu igen til 17 grader, da de fleste hotelgæster forlader hotellet i løbet af dagen for at se på lokalområdet, mødes med familie og venner osv.

  • Kl. 16 hæver vi igen temperaturen til 20 grader, da der selvfølgelig skal være lunt inden gæsten kommer hjem.

Remember: The guest can always adjust the temperature themselves, if desired.

  • Kl. 23 er der igen nattesænkning til 17 grader.

  • Kl. 5 hæves temperaturen til 20 grader.

  • At 8 AM, the temperature is lowered to 17 degrees, as the guest will be checking out on this day and is typically busy showering, eating breakfast, packing their suitcase, etc.

Bemærk, hvis gæsten selv har stillet termostaten til lavere end den temperatur, systemet er sat til at justerer op til vil der ikke ske en justering, da gæsten måske ønsker et koldt værelse at sove i. Dette respekteres naturligvis – og det sparer på energien!

How would you like the temperature settings configured at your place?

Ring til os på 73 700 100 for at høre mere